Hospital Instrument Medical Equipment Emergency Anesthesia Devices Ventilator System Nlf-200c

Customization: Available
Type: Ventilator
Group: Adult

Product Description

🔹 Basic Information
Model NO.
Ventilator System NLF-200C
LCD Display
With LCD Display
Gas Source
O2, Air
Pressure
280kpa-600kpa
Voltage
100-240V
Frequency
50Hz+-1Hz
G.W. / N.W.
90kg / 57.2kg
Packing Size
L670*W700*H1410mm
Specification
CE
Capacity
1000 PCS
📋 Product Description & Application

The CPAP System NLF-200C is specifically designed for newborn babies with stronger spontaneous breath and slight respiratory failure. It is widely applied in pediatric clinics for NCPAP oxygen uptake.

Performance and Features
CPAP ventilation mode maintains spontaneous breath and reduces breathing work for newborns.
Delivers Air/O2 mixture with adjusted O2 concentration and continuous positive pressure.
Equipped with a built-in oxygen/air blender for stable concentration adjustment.
Real-time O2 concentration monitoring with high-quality oxygen sensor and alarms.
Advanced pressure monitoring system and reliable CPAP control valve.
Integrated 3'' display for clear parameter viewing.
⚙️ Technical Parameters
Adjusting Parameters
● Inhaled O2 concentration: 21% ~ 100%
● CPAP: 0 cmH2O ~ 15 cmH2O
● Continuous flow: 2 L/min ~ 20 L/min
Monitoring Parameters
● Monitoring O2 concentration: 15% ~ 100%
● Monitoring CPAP: 0 cmH2O ~ 60 cmH2O
● Monitoring flow: 2 L/min ~ 20 L/min
Alarm & Protection
⚠️ AC power cut-off alarm
⚠️ Low air/oxygen input pressure alarm
⚠️ Unbalanced pressure alarm
⚠️ High/Low oxygen concentration alarms
⚠️ Pressure limit protection
🖼️ Product Gallery
Ventilator System NLF-200C
Medical Equipment NLF-200C Detail
Emergency Device View
CPAP System Component
❓ Frequently Asked Questions
What is the primary use of the NLF-200C CPAP system?
It is used for newborn babies with spontaneous breath and slight respiratory failure, commonly applied in pediatric clinics for oxygen therapy.
Does the system provide real-time monitoring?
Yes, it features a 3'' display and a high-quality sensor to monitor real-time oxygen concentration, CPAP levels, and continuous flow.
What are the power supply requirements?
The system supports 100-240V at 50/60Hz. If used with an air compressor, the power consumption is approximately 900VA.
How does the NLF-200C ensure patient safety?
It includes multiple safety features such as AC power cut-off alarms, pressure limit protection, and alarms for unbalanced air/oxygen input.
What is the range for oxygen concentration adjustment?
The inhaled oxygen concentration can be adjusted from 21% to 100%, and monitored from 15% to 100%.
What are the dimensions and weight of the unit?
The net weight is 57.2kg, and the wooden case packing size is L670*W700*H1410mm.

Related Products